Minimum span is 1- 2 Mtrs and Maximum span is 35 Mtrs.
If the gutter beams are RCC panels, then it can be fixed with anchor and if the gutter beams are Steel panels, then we use nuts and bolts.
No, it is not possible to fix roofing on a flat beam.
Yes, it is possible and on the steel beam a runner plate with the required degree angle has to be fixed, and plate roofing can be installed.
yes, it is possible.
yes, it can withstand wind loads up to 185 Km/hour.
Colour coated galvalume, from .8mm thickness to 1.6mm thick material depending upon the span.
350 Mpa yield strength galvalume coated steel.
Dongbu Steel, Dongkuk, Tata, JSW.
30 Years of structural stability certificate will be provided to the client.
No, since it's a curved roof it’s not safe to fix turbo ventilators on the sides, but in the case of the skylight, it can be fixed.
Each panel's hook will be inserted into the other panels Hem and it is then mechanically seamed with a seaming machine.
No Welding will be done, but it is seamed mechanically
Yes, it is available
Up to 50 Kg depending up on the span and thickness of the material
in normal cases, white and blue and for special cases, all the RAL shades are available
10000 sqft can be installed in 12 hours depending upon the site conditions